| 1. |
340.9KB - CompuMachine
Fadal Maintenance Manual Section 14 General Information Helpful Formulas Temperature Degrees Fahrenheit F 9 5 x degrees C 32 Degrees Celsius C 5 9 x degrees F 32 Conversion Factors Inch in millimeter x 0 03937 Inch in centimeter x 0 3937 Millimeter mm inch x 25 4 Centimeter cm inch x 2 54 Liter gallon U S x 3 7854 Gallon U S liter x 0 2642 Bar Pounds per Square Inch psi x 0 0689 Pounds per Square Inch psi Bar x 14 5 Newton metre N m pound foot x 14 5939 Pound foot Newton metre N m x 0 0685 Newton metre N m ounce inch x 0 00706 Ounce inch newton metre N m x 0 1416 Electrical References Formulas from Ohm s Law Amperes I Volts E Resistance R Resistance R Volts E Amperes I Volts E Amperes I x Resistance R Single Phase Kilovolt Amperes KVA Volts x Amperes 1000 Three Phase Kilovolt Amperes KVA Volts x Amperes x 1 73 1000 Expansion Formula Coefficients Expansion amount Coefficient x distance x degree of temperature change Fahrenheit Coefficients Steel 00000633 Cast Iron 00000655 Aluminum 00001244 March 2003 Section 14 General Information 473 Fadal Maintenance Manual Fadal Machining Centers Serial Numbers 474 The new serial number scheme is as follows oo 99 9999 99 9999 Machine Number 01 VMC 02 Rotary 03 Re Man Year of Month of Manufacture Manufacture Example 042000110020 04 2000 11 0020 For reference the old serial number scheme Year of Machine Month of Example 9911020 99 11 020 Manufacture Section 14 General Information March 2003 Fadal Communications Troubleshooting Environment March 2003 File Maintenance Manual For communication problems several factors must be examined Review the environment then check the file the VMC the cables the computer and finally the computer s communications software Any one of these systems can propagate a communication problem In areas where lightning strikes are common communications can be interrupted when or after lightning has struck a power line The lightning may affect the memory of the CNC control which would then have to be zeroed from the DI mode It is suggested to call a service person or see the maintenance manual for this zeroing procedure e An RS 232 surge suppressor adds protection in this kind of environ ment 1 Has the file ever successfully been transmitted to the VMC before If the file has been transmitted before has it recently been edited and has something been introduced into the file Use an editor or word processor which will show hidden characters If hidden characters are present in the file remove them 2 If the file has not been successfully transmitted use an editor or word processor which will show hidden characters If hidden characters are present in the file remove them a |
PDF Manual |
ENGLISH |